dc.description.abstract Proc. Aust. Soc. Anim. Prod. 1996 Vol. 21 A DEVICE FOR DETECTING PERIODS OF HIGH HEAT LOAD IN ANIMALS J.B. GAUGHAN, J. HOLT, B.A. YOUNG, P.J. GOODWIN, R.G. BENEKE and W. JABBOORI Dept of Animal Production, The University of Queensland, Gatton, Qld 4343 Two environmental factors responsible for depressing feed intake and decreasing productivity in dairy and feedlot cattle are high ambient temperature (T) and high relative humidity (RH) (Horst 1983). Previous and current practices to reduce heat load (combination of T, RH, solar radiation and body condition) of cattle offer either partial or high-cost solutions (Shearer et al. 1991). The thermal load monitor (TLM) was built to simulate thermal reactions of cattle to changes in T and air movement (Wd), and to detect these changes at an early stage before they impact negatively on cattle performance and welfare. The TLM consists of a solid aluminium black globe (BG) containing thermosensors connected to cooling/heating pumps and a computer-controlled monitoring system. The TLM was tested in an environmentally-controlled room over a temperature range of 24 to 48�C with Wd across the BG of 0.0 (control), 0.2,0.5, 1.0 or 2.0 m/s, at either 30 or 50% RH. The energy flux (watts, W) from or to the BG was measured and indicated either cooling (+ W) or heating (- W) to maintain the BG temperature at 38.6O C. A significant relationship exists between W and T, and W and Wd for the different temperatures (Table 1). The regression analysis indicates significant effects (PcO.001) of T and Wd on W at 50% RH (W = 50.69 + 1.33T - 0.99Wd; R* = 0.89) and at 30% RH (W = -34.65 + 0.89T - 0.39Wd; R* = 0.52). Wd had a significant effect (P<O.OOl) on W at all temperatures when tested at 50% RH, but was less consistent at 30% RH. Generally as air speed increased more energy was used to maintain globe temperature at both low and high ambient temperatures. Table 1. Least Squares means =f: SEM* of TLM energy flux (pooled) for ambient temperatures either above or below 35 'C at 30% and 50 % relative humidity SHEARER, J.K., BEEDE, D.K., BUCKLIN, R.A. and BRAY, D.R.T. (1991). Agric. Prac. 12: l-l 8. HORST, P. (1983). J. S. A.Vet. Ass. 54: 159-64. 379
dc.publisher ASAP
dc.source.uri http://www.asap.asn.au/livestocklibrary/1996/Gaughan96a.PDF
dc.subject cattle
dc.subject pulse rate
dc.subject oxygen consumption
dc.title A device for detecting periods of high heat load in animals
dc.type Research
dc.identifier.volume 21
dc.identifier.page 379


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Livestock Library


Advanced Search

Browse

My Account