Low voltage stimulation can improve the tenderness of beef loins

Livestock Library/Manakin Repository

Show simple item record

dc.contributor Hofmeyr, CD
dc.contributor Green, JM
dc.contributor Warner, RD
dc.contributor Shaw, FD
dc.date.accessioned 2012-01-25T12:32:09Z
dc.date.available 2012-01-25T12:32:09Z
dc.date.issued 1998
dc.identifier.citation Proc. Aust. Soc. Anim. Prod. (1998) 22: 297
dc.identifier.uri http://livestocklibrary.com.au/handle/1234/8925
dc.description.abstract Animal Production in Australia 1998 Vol. 22 LOW VOLTAGE STIMULATION CAN IMPROVE THE TENDERNESS OF BEEF LOINS C.D. HOFMEYR A, J.M. GREEN B , R.D. WARNERA and F.D. SHAW A B C C Victorian Institute of Animal Science, Agriculture Victoria, Werribee, Vic 3030 Australian Meat Technology, South Melbourne, Vic 3205 Food Science Australia, Tingalpa D.C., Qld 4173 It is recommended that for effective low-voltage electrical stimulation (LV-ES) of beef carcases the current pathway is via an electrode inserted into the nostril and one other electrode (Powell et al. 1986). The other electrode may be a rubbing bar that makes contact with the hindquarter of the body. With the rubbing bar electrode, any intermittent contact may lead to bouncing of the carcase and possibly to ineffective stimulation. Using the shackle as the hindquarter electrode could overcome that disadvantage but has been reported to produce ineffective stimulation (Powell et al. 1986). However, the effectiveness of a particular ES system depends not only on the electrode system but also on the electrical parameters of the stimulator and the completion of the electrical path between the carcase, rail and stimulator. Thus it is possible that, with a suitable stimulator, nostril-shackle systems could produce effective stimulation. A trial of a low voltage stimulation system was conducted at a domestic beef abattoir. The stimulator was a Koch-Britton LV-ES unit. A nostril electrode was used with a shackle forming the other electrode. Carcases were subjected to a peak voltage of 48V for 40 seconds with three seconds on and one second off. Ten carcases were stimulated using a nostril probe-shackle earth current pathway and ten carcases were unstimulated controls. The mean side weight of the stimulated group was 110.3 kg and for the control group 111.5 kg. Surface and deep butt temperatures were monitored in several sides. After overnight chilling, the striploins (longissimus dorsi) were removed for meat quality evaluation. Table 1. The ef fect of low voltage electrical stimulation on meat quality of the beef loin Control pH at 1 hour post mortem Ultimate pH Warner-Bratzler Peak shear force (kg) Sarcomere length (mm) 6.2 5.6 9.89 1.67 Shackle 5.8 5.5 6.03 1.75 s.e.d. 0.06 0.04 1.13 0.05 Significance (P) <0.001 n.s. <0.001 n.s. The pH values at one hour post mortem and the Warner-Bratzler peak shear force values were significantly different between stimulated carcases and the controls. Stimulation resulted in lower shear force values (more tender) than the control group. Chilling rates for both treatments indicated rapid chilling with deep butt temperatures reaching 20�C within 12 hours. The sarcomere length was also higher for the stimulation carcases, suggesting that the increase in tenderness was due to the prevention of cold shortening. There was a statistically significant improvement in tenderness as a result of stimulation, but the overall tenderness of the stimulated group in the trial was not optimal. If the cuts were to be sold without further ageing, it is likely that consumers would regard some of them as tough. Huffman et al. (1996) suggested that beef steaks should have a W-B shear value of 4.1 kg or less to ensure high levels (98%) of consumer acceptability. In conclusion, it was demonstrated that LV-ES using a shackle earth can be an efficient system to improve the tenderness of beef, as measured by Warner Bratzler shear force. POWELL, V.H., HARRIS, P.V. and SHORTHOSE, W.R. (1986). Food Technology in Australia 38, 230. HUFFMAN, K.L., MILLER, M.F., HOOVER, L.C., WU, C.K., BRITTIN, H.C. and RAMSEY, C.B. (1996). J. Anim. Sci. 74, 91-97. 297
dc.publisher ASAP
dc.source.uri http://www.asap.asn.au/livestocklibrary/1998/Hofmeyr98.PDF
dc.subject electrical stimulation
dc.subject tenderness
dc.subject shackle
dc.subject carcass meat
dc.subject eating quality
dc.subject electrodes
dc.title Low voltage stimulation can improve the tenderness of beef loins
dc.type Research
dc.identifier.volume 22
dc.identifier.page 297


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Livestock Library


Advanced Search

Browse

My Account